Find

GeniaAir Classic

Everything you need from a heat pump

  • Functional and compact design for easy installation
  • 70°C flow temperatures for tailored use in all homes
  • New safety concept for highest flexibility
  • R290 refrigerant with low GWP for future-proof heating
  • Easy control via smartphone and the MiGo Link app

If your house had a heating wish list, it would be completely fulfilled with the GeniaAir Classic. With a convincing output of up to 11 kW and high flow temperatures of up to 70 °C, it’s suitable for all kinds of houses – even with existing radiators. Say goodbye to limited installation options! With the new Flexible Space Function, the GeniaAir Classic air-to-water heat pump brings unparalleled flexibility to your home. Unlike older models, it can now be installed directly next to doors, windows, cellar shafts, sockets, or even outdoor lighting. And with its compact design, even the highest output unit actually fits underneath a window. Out of sight but never out of reach: your heating data is always available in the app due to the integrated connectivity.

Specifications

Specifications

HA 5-7.1 O 230VHA 7-7.1 O 230VHA 11-7.1 O
ErP
ErP Seasonal Space Heating Efficiency Low Temp ClassA+++ | D -> AA+++ | D -> AA+++ | D -> A
ErP Seasonal Space Heating Efficiency High Temp ClassA++ | D -> AA++ | D -> AA++ | D -> A
Power Output and Efficiency
Heat Output / Power Consumption / COP for A-7/W35 (acc. to EN 14511)4,84 kW / 1,70 kW / 2,91 6,37 kW / 2,39 kW / 2,6611,12 kW / 4,36 kW / 2,55
Heat Output / Power Consumption / COP for A2/W35 (acc. to EN 14511) 2,36 kW / 0,56 kW / 4,213,50 kW / 0,84 kW / 4,156,50 kW / 1,56 kW / 4,17
Heat Output / Power Consumption / COP for A7/W35 at ΔT=5 K (acc. to EN 14511)3,36 kW / 0,68 kW / 4,934,48 kW / 0,92 kW / 4,837,53 kW / 1,49 kW / 5,03
Heat Output / Power Consumption / COP for A7/W45 at ΔT=5 K (acc. to EN 14511)4,26 kW / 1,12 kW / 3,806,98 kW / 2,00 kW / 3,506,97 kW / 1,92 kW / 3,63
Heat Output / Power Consumption / COP for A-7/W55 (acc. to EN 14511)4,78 kW / 2,23 kW / 2,146,11 kW / 2,93 kW / 2,089,43 kW / 4,54 kW / 2,07
Heat Output / Power Consumption / COP for A7/W55at ΔT=8 K (acc. to EN 14511)6,35 kW / 2,12 kW / 2,996,67 kW / 2,27 kW / 2,928,49 kW / 2,73 kW / 3,10
Cooling Output / Power Consumption / EER for A35/W18 at ΔT=5 K (acc. to EN 14511) 5,61 kW / 1,32 kW / 4,357,15 kW / 1,65 kW / 4,3212,95 kW / 3,24 kW / 4,00
SCOP (Low Temperature)5,014,874,93
SCOP (High Temperature)3,73,623,66
SEER5,857,146,53
Electrical Connection
Electrical Power Consumption (max)3,2 kW3,5 kW 5,7 kW
Electrical Power Consumption (Standby Mode)8,8 W8,8 W8,8 W
Electrical Power Consumption (Standby Mode / with Flexible Space Funktion)13,9 W13,8 W20,8 W
Electrical Voltage Supply230 V (50 Hz)230 V (50 Hz)400 V (50 Hz)
Fuse TypeCharacteristic B, single-pole switchingCharacteristic B, single-pole switchingCharacteristic C (slow blow), triple-pole switching
IP Rating IPX4IPX4IPX4
Protection Class I I I
Refrigerant
RefrigerantR290R290R290
Refrigerant Quantity0,5 kg0,6 kg1,05 kg
GWP0,020,020,02
CO₂ Equivalent0,00001 t0,00001 t0,00002 t
Operation Fluids
Content Heating Circuit1,66 l1,78 l4,31 l
Hydraulics
Pump Volume Flow (min)521 l/h522 l/h1.225 l/h
Pump Volume Flow / Remaining Pump Head (max)860 l/h / 588 mbar1.275 l/h / 675 mbar2.445 l/h / 352 mbar
Noise Emission
Sound Power Level at A-7/W35 (60 % Noise reduction mode / outdoor)48,2 dB(A)49,9 dB(A)55,1 dB(A)
Sound Power Level (outdoor) (max)57,7 dB(A)60,9 dB(A)65,6 dB(A)
Sound Power Level atA7/W55 (ErP / outdoor)49 dB(A)49 dB(A)54,8 dB(A)
Connections
Connection Dimension Heating (Flow, Return)G 1 ¼″G 1 ¼″G 1 ¼″
Dimensions
Height / Width / Depth (without packaging)750 mm / 1.104 mm / 454 mm750 mm / 1.104 mm / 454 mm1.103 mm / 1.169 mm / 454 mm
Weight (without packaging)84 kg90,3 kg136,6 kg
Weight Ready for Operation84,5 kg90,9 kg 137,65 kg
Limitations
Distance (Outdoor to Last Indoor Unit) (max)20 m20 m20 m
Operating Pressure Heating Circuit (max)2,5 bar2,5 bar2,5 bar